- Configure jbod in disk genius upgrade#
- Configure jbod in disk genius plus#
- Configure jbod in disk genius zip#
This will give you a new mountpoint to store files. Mkdir /bigdir # arbitrary mountpoint name, choose your own Lvcreate -L 1000000 vgbig # size is 1000 GB, just an arbitrary value # Note: /dev/dsk/c2t*d0 should create a list of all the DS2405 disks Then DiskGenius converts the disk to HDD mode immediately. I also wanted to set up the WD RED as a JBOD, I do not have any interest in backing up the data on the NAS just need to use it as a media server. Click Yes button to continue if files on the disk have been well backed up. Now I have added a second hard disk which is a 3TB Toshiba, I have set up the Toshiba as a JBOD. Select the USB disk to be created bootable disk and choose 'Covert To HDD Mode' From Tools menu. Detailed steps are in the following: Step 1.
Configure jbod in disk genius zip#
# If there is just one group with 0x000000, then use 0x010000 as the new one If the current disk is working in FDD or ZIP mode, this function can convert it to HDD mode. # all the group files (perhaps just one) will be listed. Mkdir /dev/vgbig # vgbig is just the name I chose, you can use another name Pvcreate (for each disk in the DS2405, which you have already done) JBOD (just a bunch of disks or just a bunch of drives): JBOD (which stands for 'just a bunch of disks') generally refers to a collection of hard disks that have not been configured to act as a redundant array of independent disks ( RAID ) array. However, besides being a slower option, it doesn't allow me to use 2 disks that already have information in them, since this procedure requires clearing the disks. In this case, Linux already detects the virtual devices. So to create a new volume group, the steps are: The only way I found to use the disks in a JBOD-like manner was to configure a single RAID-0 disk group/span for each disk. You can add many more 73 GB disks, but the maximum extent count (per disk) won't allow adding the 146 GB disks. When a volume group is first created, you can specify the maximum extent count, but if you don't, the count is the calculated based on the size of the current disks (the -e max_pe option). Most of the configuration can be done from this screen by highlighting the very top line, which. The management screen shows all of the disk groups and virtual disks created on the raid controller. (See image 1) Image 1: Virtual Disk Screen. pvcreate simply initializes the disks so they can be added to a volume group.Īs I mentioned, you cannot use vgextend to add these 146 GB disks to your current vg00 because the disks are too big, that is, they require too many extents. Once booted into the configuration utility, you will initially be greeted by the Virtual Disk Screen. HPE Blog, Austria, Germany & Switzerland.You already paid for " RAID", so I'm glad you intend to finally take advantage of it. Backup, Wipe, Re-format, Restore Backup is the only method available to you.
![configure jbod in disk genius configure jbod in disk genius](https://html5.litten.com/images/raw/td2.jpg)
Configure jbod in disk genius upgrade#
One of the joys of using dangerous Drive Schemes like JBOD or RAID0 rather than using RAID solutions, is that there is no upgrade migration possible. I could do this on the dlink but understand I will have to rethink for this qnap, probably along the lines that dolbyman suggests.
![configure jbod in disk genius configure jbod in disk genius](https://tidbits.com/uploads/2018/07/Disk-Utillity-APFS.png)
Show current state: twcli /c0 show exportjbod. However, LSI/3ware recommends that the drives instead be configured as single drives.
Configure jbod in disk genius plus#
Enter controller management in the main interface of array card configuration, and then enter advanced controller. P3R is correct in that I was hoping to take my two 3tb disks and have say 1tb mirrored from disk 1 to disk 2 plus a 4tb jbod made from 2tb on disk 1 and 2tb on disk 2. The 3ware 9650SE controller can configure the drives as JBOD, which makes them usable as one large unit with the capacity of the sum of all the drives. First, confirm whether the current array card supports JBOD mode.
![configure jbod in disk genius configure jbod in disk genius](https://i0.wp.com/apkgod.net/wp-content/uploads/2019/05/MaxDataGenius_2.png)